{"id":11712,"date":"2025-12-06T15:36:37","date_gmt":"2025-12-06T10:06:37","guid":{"rendered":"https:\/\/www.mymedicplus.com\/blog\/?p=11712"},"modified":"2025-12-06T15:36:40","modified_gmt":"2025-12-06T10:06:40","slug":"complete-guide-to-the-tonometer-applanation-non-contact-air-puff","status":"publish","type":"post","link":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/","title":{"rendered":"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff)"},"content":{"rendered":"\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_81 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#1_Definition\" >1. Definition<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#What_is_a_Tonometer\" >What is a Tonometer?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#How_it_Works\" >How it Works<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Key_Components\" >Key Components<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#2_Uses\" >2. Uses<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Clinical_Applications\" >Clinical Applications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Who_Uses_It\" >Who Uses It<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#DepartmentsSettings\" >Departments\/Settings<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#3_Technical_Specifications\" >3. Technical Specifications<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Typical_Specifications\" >Typical Specifications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Variants_Sizes\" >Variants &amp; Sizes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Materials_Features\" >Materials &amp; Features<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Notable_Models\" >Notable Models<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#4_Benefits_Risks\" >4. Benefits &amp; Risks<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Advantages\" >Advantages<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Limitations\" >Limitations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Safety_Concerns_Warnings\" >Safety Concerns &amp; Warnings<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Contraindications\" >Contraindications<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#5_Regulation\" >5. Regulation<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#FDA_Class\" >FDA Class<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#EU_MDR_Class\" >EU MDR Class<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#CDSCO_Category_India\" >CDSCO Category (India)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#PMDA_Notes_Japan\" >PMDA Notes (Japan)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#ISOIEC_Standards\" >ISO\/IEC Standards<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#6_Maintenance\" >6. Maintenance<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Cleaning_Sterilization\" >Cleaning &amp; Sterilization<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Reprocessing\" >Reprocessing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Calibration\" >Calibration<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Storage\" >Storage<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#7_Procurement_Guide\" >7. Procurement Guide<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#How_to_Select_the_Device\" >How to Select the Device<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Quality_Factors\" >Quality Factors<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Certifications\" >Certifications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Compatibility\" >Compatibility<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-35\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Typical_Pricing_Range\" >Typical Pricing Range<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-36\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#8_Top_10_Manufacturers_Worldwide\" >8. Top 10 Manufacturers (Worldwide)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-37\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#9_Top_10_Exporting_Countries_Latest_Data_Trends\" >9. Top 10 Exporting Countries (Latest Data Trends)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-38\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#10_Market_Trends\" >10. Market Trends<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-39\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#11_Training\" >11. Training<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-40\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Required_Competency\" >Required Competency<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-41\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Common_User_Errors\" >Common User Errors<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-42\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#Best-Practice_Tips\" >Best-Practice Tips<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-43\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#12_FAQs\" >12. FAQs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-44\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#13_Conclusion\" >13. Conclusion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-45\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#14_References\" >14. References<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Definition\"><\/span><strong>1. Definition<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_a_Tonometer\"><\/span><strong>What is a Tonometer?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg\" alt=\"\" style=\"width:467px;height:auto\" \/><\/figure>\n\n\n\n<p>A tonometer is a specialized medical device used to measure the pressure inside the human eye, known as intraocular pressure (IOP). Elevated IOP is a primary risk factor for glaucoma, a group of eye conditions that can lead to irreversible optic nerve damage and vision loss if left undetected and untreated. This guide focuses on the two most prevalent types in clinical practice: <strong>Applanation Tonometers<\/strong> (often considered the clinical gold standard) and <strong>Non-Contact Tonometers (NCT)<\/strong>, commonly known as <strong>&#8220;Air-Puff&#8221;<\/strong> tonometers.<\/p>\n\n\n\n<p>The primary function of both is the same\u2014to provide a quantitative measurement of IOP\u2014but they achieve this through different physical principles, balancing precision, patient comfort, and clinical workflow.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_it_Works\"><\/span><strong>How it Works<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Applanation Tonometer (e.g., Goldmann):<\/strong> This method is based on the <strong>Imbert-Fick principle<\/strong>. It states that the pressure inside a perfect, dry, thin-walled sphere (P) equals the force (F) needed to flatten (applanate) a known area of its surface (A), or P = F\/A. In practice, the device uses a small, flat-tipped probe to gently touch and slightly flatten the cornea (the eye&#8217;s clear front surface). The force applied is measured and converted to a pressure reading in millimeters of mercury (mmHg). To improve accuracy, a fluorescent dye (fluorescein) and a cobalt blue light are used to create a visible ring pattern that guides the correct amount of applanation.<\/li>\n\n\n\n<li><strong>Non-Contact \/ Air-Puff Tonometer:<\/strong> This is a <strong>no-touch<\/strong> method. The patient rests their chin on a brace and looks at a fixation light inside the machine. The device emits a precisely controlled, rapid pulse of air directed at the cornea. An electro-optical system monitors the cornea. At the moment the air pulse flattens the cornea (applanation), the system records the force of the air pulse required. This force is then correlated to an IOP value. The entire process is completed in a few milliseconds.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Key_Components\"><\/span><strong>Key Components<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>For Goldmann-style Applanation Tonometer:<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>Slit Lamp Microscope:<\/strong> The tonometer is mounted on this standard ophthalmology instrument, which provides magnification and illumination.<\/li>\n\n\n\n<li><strong>Tonometer Head\/Prism:<\/strong> A disposable or sterilizable biprism that makes contact with the cornea. It splits the fluorescein-stained tear film ring into two semicircles.<\/li>\n\n\n\n<li><strong>Force Adjustment Knob\/Graduated Drum:<\/strong> Allows the user to manually adjust the force applied to the cornea. The reading (in mmHg) is taken from a scale on this drum when the semicircles are aligned correctly.<\/li>\n\n\n\n<li><strong>Cobalt Blue Filter:<\/strong> Creates the blue light needed to make the fluorescein dye fluoresce green.<\/li>\n\n\n\n<li><strong>Applanation Tip Cleaning &amp; Disinfection Supplies:<\/strong> Critical for preventing infection.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>For Non-Contact (Air-Puff) Tonometer:<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>Chin Rest &amp; Forehead Band:<\/strong> Stabilizes the patient&#8217;s head.<\/li>\n\n\n\n<li><strong>Fixation Target:<\/strong> A light for the patient to stare at, aligning the eye correctly.<\/li>\n\n\n\n<li><strong>Air Pulse Emitter\/Nozzle:<\/strong> Generates the calibrated puff of air.<\/li>\n\n\n\n<li><strong>Electro-Optical Sensor\/Alignment System:<\/strong> Detects the eye&#8217;s position and the moment of corneal applanation.<\/li>\n\n\n\n<li><strong>Microprocessor &amp; Display:<\/strong> Controls the test sequence, calculates IOP, and displays the result.<\/li>\n\n\n\n<li><strong>Printer or Data Interface (common):<\/strong> For recording results.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Uses\"><\/span><strong>2. Uses<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Clinical_Applications\"><\/span><strong>Clinical Applications<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Glaucoma Screening &amp; Diagnosis:<\/strong> The primary use. Regular IOP measurement is essential for detecting glaucoma risk.<\/li>\n\n\n\n<li><strong>Glaucoma Management &amp; Monitoring:<\/strong> Tracking IOP over time to assess the effectiveness of medications, laser treatment, or surgery.<\/li>\n\n\n\n<li><strong>Pre- and Post-Operative Assessment:<\/strong> Used before cataract, refractive, or other eye surgeries, and to monitor for pressure spikes afterward.<\/li>\n\n\n\n<li><strong>Ocular Hypertension Diagnosis:<\/strong> Identifying high IOP in the absence of glaucoma damage.<\/li>\n\n\n\n<li><strong>Routine Comprehensive Eye Exams:<\/strong> A standard part of an adult eye examination.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Who_Uses_It\"><\/span><strong>Who Uses It<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ophthalmologists<\/strong><\/li>\n\n\n\n<li><strong>Optometrists<\/strong><\/li>\n\n\n\n<li><strong>Trained Ophthalmic Technicians\/Assistants<\/strong><\/li>\n\n\n\n<li><strong>Hospital Nurses<\/strong> (in some ophthalmology wards or pre-operative units)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"DepartmentsSettings\"><\/span><strong>Departments\/Settings<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ophthalmology Clinics &amp; Private Practices<\/strong><\/li>\n\n\n\n<li><strong>Hospital Ophthalmology Departments<\/strong><\/li>\n\n\n\n<li><strong>Optometry Practices<\/strong><\/li>\n\n\n\n<li><strong>Ambulatory Surgery Centers<\/strong><\/li>\n\n\n\n<li><strong>Some General Practice\/Internal Medicine clinics<\/strong> (for basic screening, often with an NCT).<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Technical_Specifications\"><\/span><strong>3. Technical Specifications<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Typical_Specifications\"><\/span><strong>Typical Specifications<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Measurement Range:<\/strong> Typically 0-60 mmHg.<\/li>\n\n\n\n<li><strong>Resolution:<\/strong> Usually 1 mmHg.<\/li>\n\n\n\n<li><strong>Accuracy:<\/strong> Goldmann applanation is considered accurate to within \u00b10.5 mmHg under ideal conditions. NCTs generally have a slightly wider variability.<\/li>\n\n\n\n<li><strong>Measurement Time:<\/strong> NCT: &lt;5 milliseconds per puff. Goldmann: 10-30 seconds per eye.<\/li>\n\n\n\n<li><strong>Power Source:<\/strong> AC power for main units; backup batteries may be present.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Variants_Sizes\"><\/span><strong>Variants &amp; Sizes<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Portable\/Mobile Tonometers:<\/strong> Hand-held versions of both applanation (e.g., Perkins, Tono-Pen) and air-puff types for bedside or home use.<\/li>\n\n\n\n<li><strong>Rebound Tonometer (iCare):<\/strong> A distinct, hand-held variant that uses a lightweight, magnetized probe to &#8220;tap&#8221; the cornea. Gaining popularity due to its portability and no need for anesthetic drops.<\/li>\n\n\n\n<li><strong>Non-Contact Pachymeter-Tonometer Combos:<\/strong> Many modern NCTs also measure central corneal thickness (pachymetry), a critical factor for accurate IOP interpretation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Materials_Features\"><\/span><strong>Materials &amp; Features<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Materials:<\/strong> Housings are high-grade plastics and metals. Prisms are acrylic or glass. Nozzles are precision-engineered plastic or metal.<\/li>\n\n\n\n<li><strong>Key Features:<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>Auto-Fire &amp; Alignment:<\/strong> Modern NCTs auto-trigger when properly aligned.<\/li>\n\n\n\n<li><strong>Multiple Measurements &amp; Averaging:<\/strong> Takes several readings and provides an average.<\/li>\n\n\n\n<li><strong>Corneal Compensation:<\/strong> Some advanced models adjust the IOP reading based on measured corneal properties (like thickness or biomechanics).<\/li>\n\n\n\n<li><strong>Electronic Data Management:<\/strong> Direct EHR integration or USB data export.<\/li>\n\n\n\n<li><strong>&#8220;Soft-Puff&#8221; Technology:<\/strong> Gentler air pulses to reduce patient anxiety.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Notable_Models\"><\/span><strong>Notable Models<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Goldmann Applanation Tonometer:<\/strong> The ubiquitous benchmark, often mounted on Haag-Streit or Reichert slit lamps.<\/li>\n\n\n\n<li><strong>Perkins Mk3:<\/strong> Hand-held applanation tonometer.<\/li>\n\n\n\n<li><strong>Reichert Tono-Pen Avia:<\/strong> Hand-held electronic applanation device.<\/li>\n\n\n\n<li><strong>Canon TX-F \/ Nidek NT-510\/530:<\/strong> Advanced NCTs with pachymetry.<\/li>\n\n\n\n<li><strong>Topcon CT-800\/CT-1P:<\/strong> Popular table-top and portable NCTs.<\/li>\n\n\n\n<li><strong>Keeler Pulsair:<\/strong> A portable, easy-to-use NCT.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Benefits_Risks\"><\/span><strong>4. Benefits &amp; Risks<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Advantages\"><\/span><strong>Advantages<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Applanation (Goldmann):<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>Gold Standard:<\/strong> Highest accepted clinical accuracy.<\/li>\n\n\n\n<li><strong>High Precision:<\/strong> Excellent for monitoring subtle changes.<\/li>\n\n\n\n<li><strong>Direct Visualization:<\/strong> The clinician can assess ocular surface quality during measurement.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Non-Contact (Air-Puff):<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>No Contact:<\/strong> Eliminates risk of corneal abrasion and cross-infection from the probe.<\/li>\n\n\n\n<li><strong>No Anesthesia Required:<\/strong> More comfortable, faster workflow.<\/li>\n\n\n\n<li><strong>Ease of Use:<\/strong> Less training required for basic operation.<\/li>\n\n\n\n<li><strong>Excellent for Screening &amp; Pediatrics:<\/strong> Well-suited for uncooperative or anxious patients.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Limitations\"><\/span><strong>Limitations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Applanation:<\/strong> Requires topical anesthetic and fluorescein dye. Skill-dependent. Risk of cross-contamination if not cleaned properly. Affected by corneal properties (thickness, rigidity).<\/li>\n\n\n\n<li><strong>Non-Contact:<\/strong> Generally considered slightly less accurate\/repeatable than Goldmann. Readings can be influenced by corneal biomechanics, patient movement, or improper alignment. The air puff can startle patients, causing a blink and an unreliable reading.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Safety_Concerns_Warnings\"><\/span><strong>Safety Concerns &amp; Warnings<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Infection Control:<\/strong> <strong>The highest risk with applanation tonometry is transmission of pathogens (like adenovirus or prions).<\/strong> Prisms must be disinfected according to strict protocols or be single-use. The tonometer head must not touch eyelids or lashes.<\/li>\n\n\n\n<li><strong>Corneal Abrasion:<\/strong> Possible with applanation if done incorrectly or if the patient moves suddenly.<\/li>\n\n\n\n<li><strong>Chemical Irritation:<\/strong> From improper use of anesthetic or fluorescein.<\/li>\n\n\n\n<li><strong>Patient Anxiety:<\/strong> Particularly with the NCT&#8217;s sudden air puff.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Contraindications\"><\/span><strong>Contraindications<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Active Eye Infection<\/strong> (e.g., conjunctivitis, keratitis).<\/li>\n\n\n\n<li><strong>Corneal Trauma, Ulcer, or Epithelial Defect.<\/strong><\/li>\n\n\n\n<li><strong>Recent Eye Surgery<\/strong> (depends on the procedure; surgeon discretion is needed).<\/li>\n\n\n\n<li><strong>Inability to Position or Cooperate<\/strong> (may require an alternative method like a rebound tonometer).<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Regulation\"><\/span><strong>5. Regulation<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"FDA_Class\"><\/span><strong>FDA Class<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Class II medical device (moderate to high risk). Subject to special controls (performance standards, post-market surveillance, labeling requirements). 510(k) clearance is typically required.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"EU_MDR_Class\"><\/span><strong>EU MDR Class<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Class IIa (devices for diagnosis or monitoring, for direct contact with the eye). Requires conformity assessment by a Notified Body.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"CDSCO_Category_India\"><\/span><strong>CDSCO Category (India)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Class B (moderate risk). Requires a license from the state licensing authority under the Medical Device Rules, 2017.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"PMDA_Notes_Japan\"><\/span><strong>PMDA Notes (Japan)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Class II (controlled medical devices). Requires certification from a Registered Certification Body (RCB). JIS T 7312 is the relevant Japanese Industrial Standard for non-contact tonometers.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"ISOIEC_Standards\"><\/span><strong>ISO\/IEC Standards<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>ISO 8612:2009:<\/strong> &#8220;Ophthalmic instruments \u2014 Tonometers.&#8221;<\/li>\n\n\n\n<li><strong>ISO 15004-1:<\/strong> Ophthalmic instruments \u2014 Fundamental requirements and test methods.<\/li>\n\n\n\n<li><strong>IEC 60601-1:<\/strong> General safety requirements for medical electrical equipment.<\/li>\n\n\n\n<li><strong>ISO 13485:<\/strong> Quality management systems for medical device manufacturers.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Maintenance\"><\/span><strong>6. Maintenance<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cleaning_Sterilization\"><\/span><strong>Cleaning &amp; Sterilization<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Applanation Prism\/Tip:<\/strong> The most critical component. <strong>Disinfect between every patient.<\/strong> Wipe with 70% isopropyl alcohol, hydrogen peroxide 3%, or a dilute sodium hypochlorite solution (1:10 bleach). Follow manufacturer instructions meticulously. Single-use disposable tips\/prism covers are highly recommended.<\/li>\n\n\n\n<li><strong>NCT Nozzle Tip:<\/strong> Wipe the exterior daily with a soft cloth dampened with alcohol. Some models have disposable tip covers.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Reprocessing\"><\/span><strong>Reprocessing<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Applanation tonometers are <strong>semi-critical devices<\/strong> (contact mucous membranes). High-level disinfection is mandatory. <strong>Never autoclave a reusable prism unless explicitly stated by the manufacturer.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Calibration\"><\/span><strong>Calibration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Goldmann:<\/strong> The calibration should be checked daily or weekly using the manufacturer&#8217;s provided test weight (typically 2.0 or 6.0 grams). The scale should read &#8220;0&#8221; and the test weight value accurately.<\/li>\n\n\n\n<li><strong>NCT:<\/strong> Requires periodic calibration by a qualified service technician as per the maintenance schedule (often annually). Many have internal self-checks.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Storage\"><\/span><strong>Storage<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Store in a clean, dry environment. Protect from dust, extreme temperatures, and direct sunlight. Applanation prisms should be stored disinfected and dry.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"7_Procurement_Guide\"><\/span><strong>7. Procurement Guide<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_to_Select_the_Device\"><\/span><strong>How to Select the Device<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Consider:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Clinical Need:<\/strong> High-volume screening (NCT) vs. specialized glaucoma management (Goldmann).<\/li>\n\n\n\n<li><strong>Patient Demographics:<\/strong> Children or highly anxious patients may benefit from an NCT or rebound tonometer.<\/li>\n\n\n\n<li><strong>Workflow &amp; Staff Skill:<\/strong> NCTs are faster and easier to train on. Goldmann requires a skilled operator.<\/li>\n\n\n\n<li><strong>Budget:<\/strong> Includes initial cost, cost of consumables (prisms, tips, anesthetic), and service contracts.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Quality_Factors\"><\/span><strong>Quality Factors<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Measurement Consistency (Repeatability)<\/strong><\/li>\n\n\n\n<li><strong>Ease of Alignment and Operation<\/strong><\/li>\n\n\n\n<li><strong>Durability and Build Quality<\/strong><\/li>\n\n\n\n<li><strong>Manufacturer Support &amp; Service Network<\/strong><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Certifications\"><\/span><strong>Certifications<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Look for <strong>CE Marking<\/strong> (EU), <strong>FDA 510(k) Clearance<\/strong> (US), and evidence of compliance with <strong>ISO 13485<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Compatibility\"><\/span><strong>Compatibility<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ensures compatibility with existing practice management\/EHR software for data transfer.<\/li>\n\n\n\n<li>Goldmann tonometers must be compatible with your existing slit lamp model.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Typical_Pricing_Range\"><\/span><strong>Typical Pricing Range<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Non-Contact Tonometer (NCT):<\/strong> $5,000 &#8211; $25,000 USD.<\/li>\n\n\n\n<li><strong>Goldmann Applanation Tonometer (slit lamp mounted):<\/strong> $1,500 &#8211; $5,000 (for the tonometer unit itself, excluding the slit lamp).<\/li>\n\n\n\n<li><strong>Portable\/Handheld Devices (Tono-Pen, Rebound):<\/strong> $2,500 &#8211; $6,000 USD.<\/li>\n\n\n\n<li><em>Note: Prices vary significantly based on features, brand, and region.<\/em><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"8_Top_10_Manufacturers_Worldwide\"><\/span><strong>8. Top 10 Manufacturers (Worldwide)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Haag-Streit AG (Switzerland):<\/strong> Global leader in diagnostic ophthalmic equipment. Maker of the iconic <strong>Goldmann Applanation Tonometer<\/strong>.<\/li>\n\n\n\n<li><strong>Topcon Corporation (Japan):<\/strong> Major player in ophthalmic and optical equipment. Wide range of NCTs and imaging devices.<\/li>\n\n\n\n<li><strong>Nidek Co., Ltd. (Japan):<\/strong> Renowned for lasers and diagnostic devices like the <strong>NT-510\/530<\/strong> series NCTs.<\/li>\n\n\n\n<li><strong>Carl Zeiss Meditec AG (Germany):<\/strong> Premium manufacturer of integrated ophthalmic workstations and diagnostic devices.<\/li>\n\n\n\n<li><strong>Reichert Technologies (USA)<\/strong> (subsidiary of AMETEK): Known for the <strong>Tono-Pen<\/strong> and <strong>Goldmann-compatible<\/strong> tonometers.<\/li>\n\n\n\n<li><strong>Canon Medical Systems (Japan):<\/strong> Produces highly regarded NCTs like the <strong>TX-F<\/strong> series.<\/li>\n\n\n\n<li><strong>Keeler Ltd. (UK\/USA):<\/strong> Specializes in ophthalmic instruments, including the <strong>Pulsair<\/strong> NCT.<\/li>\n\n\n\n<li><strong>iCare Finland Oy (Finland):<\/strong> Innovator and dominant player in <strong>rebound tonometry<\/strong> (iCare HOME, iCare TA01i).<\/li>\n\n\n\n<li><strong>Kowa Company Ltd. (Japan):<\/strong> Offers a range of ophthalmic devices, including portable NCTs.<\/li>\n\n\n\n<li><strong>Rexxam Co., Ltd. (Japan):<\/strong> Important manufacturer of ophthalmic equipment, including NCTs and applanation tonometers.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"9_Top_10_Exporting_Countries_Latest_Data_Trends\"><\/span><strong>9. Top 10 Exporting Countries (Latest Data Trends)<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><em>(Based on analysis of global medical device trade data for ophthalmic instruments)<\/em><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>United States:<\/strong> Major hub for high-tech medical device manufacturing and re-export.<\/li>\n\n\n\n<li><strong>Germany:<\/strong> Home to Haag-Streit and Zeiss; a center of precision engineering.<\/li>\n\n\n\n<li><strong>Japan:<\/strong> Home to Topcon, Nidek, Canon, and Kowa; dominant in advanced optoelectronics.<\/li>\n\n\n\n<li><strong>Switzerland:<\/strong> Headquarters of Haag-Streit, with a long history of precision instrument export.<\/li>\n\n\n\n<li><strong>China:<\/strong> Growing as a manufacturer and exporter of mid-range diagnostic devices.<\/li>\n\n\n\n<li><strong>Netherlands:<\/strong> Key European distribution and logistics hub for medical devices.<\/li>\n\n\n\n<li><strong>United Kingdom:<\/strong> Historical strength in medical optics (Keeler).<\/li>\n\n\n\n<li><strong>France:<\/strong> Strong domestic medical device sector with significant exports.<\/li>\n\n\n\n<li><strong>Finland:<\/strong> Driven primarily by the global success of iCare&#8217;s rebound tonometers.<\/li>\n\n\n\n<li><strong>Italy:<\/strong> Notable manufacturer of ophthalmic equipment components and systems.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"10_Market_Trends\"><\/span><strong>10. Market Trends<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Current Global Trends:<\/strong> Growth is driven by an aging global population (increasing glaucoma prevalence) and rising awareness of eye health. There is a shift towards portability and point-of-care testing.<\/li>\n\n\n\n<li><strong>New Technologies:<\/strong> Integration of <strong>artificial intelligence (AI)<\/strong> for better alignment, artifact rejection, and data interpretation. Development of devices that measure <strong>corneal biomechanical properties<\/strong> (e.g., Corvis ST) to provide a &#8220;correction factor&#8221; for IOP.<\/li>\n\n\n\n<li><strong>Demand Drivers:<\/strong> Increasing prevalence of diabetes and myopia (risk factors for glaucoma), expansion of optometric services, and tele-ophthalmology initiatives requiring easy-to-use devices.<\/li>\n\n\n\n<li><strong>Future Insights:<\/strong> Expect continued growth of <strong>home tonometry<\/strong> (like the iCare HOME) for improved glaucoma monitoring. Further integration of tonometry with <strong>optical coherence tomography (OCT)<\/strong> and other imaging modalities into single diagnostic platforms.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"11_Training\"><\/span><strong>11. Training<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Required_Competency\"><\/span><strong>Required Competency<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Goldmann Applanation:<\/strong> Requires significant practice. Competency includes proficiency with the slit lamp, proper instillation of drops, alignment, endpoint interpretation (correct fluorescein mire pattern), and disinfection.<\/li>\n\n\n\n<li><strong>NCT:<\/strong> Lower barrier to entry. Training focuses on proper patient positioning, alignment, and recognizing unreliable readings due to blinks or poor fixation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Common_User_Errors\"><\/span><strong>Common User Errors<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Applanation:<\/strong> Pressing on the eyelid, incorrect fluorescein amount (too much or too little), misalignment of the mires, improper calibration, and inadequate disinfection.<\/li>\n\n\n\n<li><strong>NCT:<\/strong> Poor patient head positioning, firing when the eye is misaligned, taking measurements on a patient with excessive tearing.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Best-Practice_Tips\"><\/span><strong>Best-Practice Tips<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>For All:<\/strong> Calibrate regularly. Explain the procedure to the patient to reduce anxiety.<\/li>\n\n\n\n<li><strong>For Applanation:<\/strong> Use the thinnest possible fluorescein strip. Gently hold lids open without pressing on the globe. Take the average of 2-3 readings.<\/li>\n\n\n\n<li><strong>For NCT:<\/strong> Ensure the patient is relaxed and blinking normally before the test. Use the instrument&#8217;s alignment feedback system diligently. Take multiple readings and note the standard deviation.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"12_FAQs\"><\/span><strong>12. FAQs<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>1. Which is more accurate, the &#8220;air puff&#8221; or the &#8220;blue light&#8221; test?<\/strong><br>The Goldmann applanation (&#8220;blue light&#8221; test with the slit lamp) is considered the clinical gold standard for accuracy. Modern air-puff (NCT) devices are very good for screening and monitoring but may have slightly more variability.<\/p>\n\n\n\n<p><strong>2. Does the air puff tonometer hurt?<\/strong><br>No, it does not hurt. There is no contact. However, the sudden air puff can be startling and cause a brief reflex blink, which is why it&#8217;s important to relax.<\/p>\n\n\n\n<p><strong>3. Why do I need eye drops for one test but not the other?<\/strong><br>The applanation tonometer touches your cornea. The numbing drop prevents discomfort, and the yellow dye (fluorescein) helps the clinician see the measurement endpoint. The air-puff test doesn&#8217;t touch the eye, so no drops are needed.<\/p>\n\n\n\n<p><strong>4. Can I wear contact lenses during the test?<\/strong><br>No. You must remove soft contact lenses for both tests. For applanation, you must also remove rigid gas permeable lenses well in advance (often several hours) as they can alter corneal shape.<\/p>\n\n\n\n<p><strong>5. How often should I have my eye pressure checked?<\/strong><br>Adults over 40 should have it checked as part of a comprehensive eye exam every 1-2 years. If you have risk factors for glaucoma (family history, high myopia, diabetes), your eye doctor will recommend more frequent checks.<\/p>\n\n\n\n<p><strong>6. Can a high pressure reading mean I have glaucoma?<\/strong><br>Not necessarily. It means you have <strong>ocular hypertension<\/strong>, a key risk factor. A glaucoma diagnosis requires evidence of optic nerve damage, which is assessed through additional tests like visual field testing and optic nerve imaging.<\/p>\n\n\n\n<p><strong>7. Why did the technician take multiple &#8220;puffs&#8221;?<\/strong><br>To ensure a consistent, reliable reading. The device often discards poor readings (from blinks) and averages several good ones.<\/p>\n\n\n\n<p><strong>8. Is it safe to have this test done if I have an eye infection?<\/strong><br>No. You should inform your doctor. Tonometer contact (especially applanation) can spread infection. The test will likely be postponed.<\/p>\n\n\n\n<p><strong>9. My home tonometer gives a different reading than the clinic&#8217;s. Which is correct?<\/strong><br>Variations are common due to different technologies, time of day (IOP fluctuates), and technique. Share your home readings with your doctor, who will interpret them in context. The in-clinic Goldmann measurement is the benchmark for clinical decisions.<\/p>\n\n\n\n<p><strong>10. What does a &#8220;high&#8221; reading mean?<\/strong><br>Normal IOP is typically between 10-21 mmHg. A consistently higher reading is a risk factor for glaucoma. Your doctor will consider this number alongside all other examination findings before determining a treatment plan.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"13_Conclusion\"><\/span><strong>13. Conclusion<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The tonometer, in its applanation and non-contact forms, remains an indispensable tool in global eye care. It is the frontline device for detecting and managing glaucoma, a leading cause of irreversible blindness. While the Goldmann applanation method sets the standard for precision in clinical decision-making, non-contact tonometers offer unparalleled advantages in speed, comfort, and infection control for screening and routine monitoring. Understanding their principles, proper use, maintenance, and limitations is crucial for any eye care professional. As technology evolves with portability, home monitoring, and advanced corneal analysis, the fundamental role of accurate IOP measurement in preserving sight will only grow in importance.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"14_References\"><\/span><strong>14. References<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>American Academy of Ophthalmology. (2022). <em>Basic and Clinical Science Course (BCSC), Section 10: Glaucoma.<\/em><\/li>\n\n\n\n<li>International Organization for Standardization. (2009). <em>ISO 8612:2009 Ophthalmic instruments \u2014 Tonometers.<\/em><\/li>\n\n\n\n<li>U.S. Food and Drug Administration (FDA). (2023). <em>Device Classification Database.<\/em><\/li>\n\n\n\n<li>European Commission. (2017). <em>Regulation (EU) 2017\/745 on medical devices (MDR).<\/em><\/li>\n\n\n\n<li>Central Drugs Standard Control Organization (CDSCO). (2017). <em>Medical Device Rules.<\/em><\/li>\n\n\n\n<li>Whitacre, M. M., &amp; Stein, R. A. (1993). Sources of error with use of Goldmann-type tonometers. <em>Survey of Ophthalmology, 38<\/em>(1), 1-30.<\/li>\n\n\n\n<li>Forbes, M., Pico, G., &amp; Grolman, B. (1974). A noncontact applanation tonometer. <em>Archives of Ophthalmology, 91<\/em>(2), 134-140.<\/li>\n\n\n\n<li>Global Market Insights Inc. (2023). <em>Tonometer Market Size Report, 2023-2032.<\/em><\/li>\n\n\n\n<li>Haag-Streit AG. (2023). <em>Goldmann Applanation Tonometer Operating Manual.<\/em><\/li>\n\n\n\n<li>iCare Finland Oy. (2023). <em>Clinical Evidence for Rebound Tonometry.<\/em><\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>1. Definition What is a Tonometer? A tonometer is a specialized medical device used to measure the pressure inside the [&hellip;]<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6461],"tags":[],"class_list":["post-11712","post","type-post","status-publish","format-standard","hentry","category-health-fitness"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff) - MyMedicPlus<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff) - MyMedicPlus\" \/>\n<meta property=\"og:description\" content=\"1. Definition What is a Tonometer? A tonometer is a specialized medical device used to measure the pressure inside the [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/\" \/>\n<meta property=\"og:site_name\" content=\"MyMedicPlus\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-06T10:06:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-06T10:06:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg\" \/>\n<meta name=\"author\" content=\"pritesh\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"pritesh\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/\"},\"author\":{\"name\":\"pritesh\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/ca4e4f6ef4b235e39026555fd129e738\"},\"headline\":\"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff)\",\"datePublished\":\"2025-12-06T10:06:37+00:00\",\"dateModified\":\"2025-12-06T10:06:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/\"},\"wordCount\":2741,\"image\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg\",\"articleSection\":[\"Health &amp; Fitness\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/\",\"url\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/\",\"name\":\"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff) - MyMedicPlus\",\"isPartOf\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg\",\"datePublished\":\"2025-12-06T10:06:37+00:00\",\"dateModified\":\"2025-12-06T10:06:40+00:00\",\"author\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/ca4e4f6ef4b235e39026555fd129e738\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage\",\"url\":\"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg\",\"contentUrl\":\"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mymedicplus.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/#website\",\"url\":\"https:\/\/www.mymedicplus.com\/blog\/\",\"name\":\"MyMedicPlus\",\"description\":\"One Blog Daily For Health And Fitness\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mymedicplus.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/ca4e4f6ef4b235e39026555fd129e738\",\"name\":\"pritesh\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/231a0e8b7a02636f2fbacf8dcf4494cb1cc0d49ecc9a8165fbaeaeeaf102641a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/231a0e8b7a02636f2fbacf8dcf4494cb1cc0d49ecc9a8165fbaeaeeaf102641a?s=96&d=mm&r=g\",\"caption\":\"pritesh\"},\"url\":\"https:\/\/www.mymedicplus.com\/blog\/author\/priteshgeek\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff) - MyMedicPlus","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/","og_locale":"en_US","og_type":"article","og_title":"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff) - MyMedicPlus","og_description":"1. Definition What is a Tonometer? A tonometer is a specialized medical device used to measure the pressure inside the [&hellip;]","og_url":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/","og_site_name":"MyMedicPlus","article_published_time":"2025-12-06T10:06:37+00:00","article_modified_time":"2025-12-06T10:06:40+00:00","og_image":[{"url":"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg","type":"","width":"","height":""}],"author":"pritesh","twitter_card":"summary_large_image","twitter_misc":{"Written by":"pritesh","Est. reading time":"13 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#article","isPartOf":{"@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/"},"author":{"name":"pritesh","@id":"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/ca4e4f6ef4b235e39026555fd129e738"},"headline":"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff)","datePublished":"2025-12-06T10:06:37+00:00","dateModified":"2025-12-06T10:06:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/"},"wordCount":2741,"image":{"@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage"},"thumbnailUrl":"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg","articleSection":["Health &amp; Fitness"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/","url":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/","name":"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff) - MyMedicPlus","isPartOf":{"@id":"https:\/\/www.mymedicplus.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage"},"image":{"@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage"},"thumbnailUrl":"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg","datePublished":"2025-12-06T10:06:37+00:00","dateModified":"2025-12-06T10:06:40+00:00","author":{"@id":"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/ca4e4f6ef4b235e39026555fd129e738"},"breadcrumb":{"@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#primaryimage","url":"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg","contentUrl":"https:\/\/5.imimg.com\/data5\/GJ\/PL\/MY-41112898\/tonometer-500x500.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mymedicplus.com\/blog\/complete-guide-to-the-tonometer-applanation-non-contact-air-puff\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mymedicplus.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Complete Guide to the Tonometer (Applanation &amp; Non-Contact\/Air-Puff)"}]},{"@type":"WebSite","@id":"https:\/\/www.mymedicplus.com\/blog\/#website","url":"https:\/\/www.mymedicplus.com\/blog\/","name":"MyMedicPlus","description":"One Blog Daily For Health And Fitness","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mymedicplus.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/ca4e4f6ef4b235e39026555fd129e738","name":"pritesh","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mymedicplus.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/231a0e8b7a02636f2fbacf8dcf4494cb1cc0d49ecc9a8165fbaeaeeaf102641a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/231a0e8b7a02636f2fbacf8dcf4494cb1cc0d49ecc9a8165fbaeaeeaf102641a?s=96&d=mm&r=g","caption":"pritesh"},"url":"https:\/\/www.mymedicplus.com\/blog\/author\/priteshgeek\/"}]}},"_links":{"self":[{"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/posts\/11712","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/comments?post=11712"}],"version-history":[{"count":1,"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/posts\/11712\/revisions"}],"predecessor-version":[{"id":11713,"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/posts\/11712\/revisions\/11713"}],"wp:attachment":[{"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/media?parent=11712"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/categories?post=11712"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mymedicplus.com\/blog\/wp-json\/wp\/v2\/tags?post=11712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}