Thoracostomy kit: Uses, Safety, Operation, and top Manufacturers & Suppliers

Table of Contents

Introduction

A Thoracostomy kit is a sterile, packaged set of instruments and consumables used to support tube thoracostomy (commonly called chest tube insertion) so air or fluid can be drained from the pleural space. In acute care, that ability to establish pleural drainage can be time-critical and resource-intensive, requiring well-coordinated people, processes, and hospital equipment.

For hospital administrators and operations leaders, the Thoracostomy kit matters because it sits at the intersection of emergency readiness, standardization, infection control, and supply chain resilience. For clinicians, it is a practical way to reduce setup friction and ensure essential components are available at the point of care. For biomedical engineers and procurement teams, it raises important questions about product configuration, compatibility with chest drainage systems and suction sources, traceability, storage, and vendor support.

This article provides a globally relevant, safety-focused overview of Thoracostomy kit use in hospitals and clinics. You will learn what a Thoracostomy kit typically includes (and what varies by manufacturer), when it is generally used, what to have in place before starting, a high-level operating workflow, patient safety and monitoring considerations, how teams commonly interpret drainage-related outputs, what to do when problems occur, and practical infection control principles. It also includes a non-promotional overview of the manufacturer/OEM landscape, distributor roles, and country-by-country market dynamics.

This is general information for trained healthcare professionals and healthcare operations teams; it is not medical advice. Always follow your facility’s protocols, competency requirements, and the manufacturer’s Instructions for Use (IFU).

What is Thoracostomy kit and why do we use it?

Definition and purpose

A Thoracostomy kit is a medical device package (often a single-use sterile procedure tray) assembled to support the placement of a pleural drain (chest tube or catheter). The core purpose is operational: to provide a ready-to-use, sterile selection of tools and consumables so the clinical team can perform the procedure efficiently and consistently, especially in urgent settings.

A Thoracostomy kit typically supports one of two broad procedural approaches (the exact approach depends on local practice and the kit design):

  • “Open” or blunt-dissection chest tube placement (commonly used for larger-bore tubes in some settings)
  • Guidewire-based (Seldinger-style) placement (commonly used for smaller-bore catheters in some settings)

Kits may be marketed as chest tube insertion kits, pleural drainage kits, thoracostomy trays, or procedure sets. Naming is not fully standardized internationally.

What’s usually inside (and what varies)

Contents vary by manufacturer, region, and whether the kit is intended for large-bore tubes, small-bore catheters, or both. Typical components may include:

  • Sterile drapes and a tray/work surface
  • Scalpel
  • Syringes and needles (often for local anesthetic and aspiration steps; exact sizes vary by manufacturer)
  • Forceps, clamps, scissors, and/or needle holders (sometimes included; sometimes excluded)
  • Dilators (more common in guidewire-based kits)
  • Guidewire and introducer needle (in guidewire-based kits)
  • Chest tube or pleural catheter (may be included or supplied separately; varies by manufacturer and contract configuration)
  • Suture material and dressing supplies (may be included; varies by manufacturer)
  • Connecting tubing/adapters (may be included; compatibility varies)
  • Labels and documentation items (occasionally included; varies by manufacturer)

Operationally important note for procurement teams: the Thoracostomy kit may not include the chest drainage unit (collection chamber and water seal) or the suction regulator. Those are often separate items of medical equipment and may be procured under different contracts, with different maintenance and training requirements.

Common clinical settings and workflows

Thoracostomy capability is required across a wide set of hospital services, which is why kit standardization often becomes a facility-wide issue rather than a single-department preference. Common areas that stock or use a Thoracostomy kit include:

  • Emergency departments and trauma bays
  • Intensive care units (adult, pediatric, neonatal—kit design may differ)
  • Operating rooms and post-anesthesia care units
  • Interventional radiology or procedure rooms (especially for image-guided small-bore catheter workflows)
  • Inpatient wards with rapid response teams (varies by facility policy)
  • Ambulance/prehospital or field hospitals (in certain systems; configuration typically simplified)

Because the procedure interacts with oxygen delivery, monitoring, imaging, and suction, the Thoracostomy kit is often part of a broader “pleural drainage readiness” bundle rather than a standalone clinical device.

Key benefits in patient care and hospital operations

While clinical outcomes depend on patient factors and clinician skill, a well-specified Thoracostomy kit can improve reliability and reduce process variation. Typical operational benefits include:

  • Faster time-to-setup in urgent situations due to fewer missing items
  • Standardized component selection, supporting training and competency checks
  • Improved sterility assurance through controlled packaging and reduced ad hoc item gathering
  • Simplified inventory management (one SKU can represent an entire procedure setup)
  • Better traceability through consistent labeling, lot tracking, and (where available) Unique Device Identification (UDI)
  • Reduced waste from over-opening multiple packs “just in case” (depends on kit design and local practice)
  • More predictable procurement and budgeting when kits are standardized across departments

For administrators, these benefits translate into fewer delays, fewer last-minute substitutions, and a clearer line of sight from policy to bedside execution.

When should I use Thoracostomy kit (and when should I not)?

Appropriate use cases (general, protocol-driven)

A Thoracostomy kit is generally used when a clinical team needs to establish pleural drainage using a tube or catheter, according to local protocols and clinician judgment. Common categories of use include:

  • Air drainage scenarios (for example, pneumothorax-related workflows)
  • Fluid drainage scenarios (for example, blood, effusions, or infected collections—terminology and treatment pathways vary)
  • Post-operative or post-procedural drainage where pleural drainage is part of routine surgical care
  • Trauma care pathways where pleural compromise may be present
  • Critical care management where ongoing pleural drainage is needed and must integrate with ventilation and monitoring

From an operations perspective, the “when” is often defined by service line policies: emergency medicine, trauma surgery, thoracic surgery, and ICU teams may each have distinct criteria, tube size preferences, and required adjuncts (for example, ultrasound availability or sedation support).

Situations where it may not be suitable

Even when pleural drainage is needed, a particular Thoracostomy kit may be a poor fit for the specific situation. Non-exhaustive examples include:

  • Mismatched device type: a large-bore tube kit may not match a facility’s preferred small-bore catheter pathway (or vice versa).
  • Inadequate imaging or monitoring environment: some settings may not meet the facility’s minimum requirements for safe procedure performance.
  • Lack of trained staff: if a trained operator and support team are not available, using the kit does not “solve” the competency gap.
  • Component incompatibility: connectors, tubing sizes, or drainage unit interfaces may not match existing hospital equipment.
  • Patient-specific complexity: certain anatomical or clinical circumstances may require specialist involvement, alternative techniques, or different device sets. Determining this is clinical decision-making and varies by facility.

For procurement teams, this is why it is risky to treat Thoracostomy kits as interchangeable commodities without confirming clinical pathways, compatibility, and training implications.

General safety cautions and contraindications (non-clinical framing)

Tube thoracostomy is an invasive procedure with recognized risks. The Thoracostomy kit does not reduce those risks by itself; it only helps deliver the procedure in a controlled, standardized way. General cautions include:

  • Use only by trained clinicians with documented competency, consistent with local credentialing.
  • Do not use if sterile integrity is compromised (damaged packaging, broken seals, wet packaging, missing sterility indicators—follow IFU).
  • Do not use expired kits or kits outside labeled storage conditions.
  • Avoid unapproved substitutions (for example, mixing parts from different systems) unless your facility has assessed compatibility and risk.
  • Be cautious with single-use labeling: many components are intended for one-time use only; reprocessing can create infection control and performance risks.

Potential clinical contraindications and precautions exist (for example, bleeding risk, anatomical considerations, local infection, or other patient factors), but these require clinician assessment and are outside the scope of general operational guidance. Facilities should ensure protocols address these considerations and include escalation pathways (for example, thoracic surgery or interventional radiology consultation where appropriate).

What do I need before starting?

People, roles, and competency expectations

Because a Thoracostomy kit supports an invasive procedure, facilities typically define minimum staffing and competency requirements. Common role expectations include:

  • Primary operator: credentialed clinician trained in the procedure and complication recognition.
  • Assistant: supports sterile field, instrument handling, and securing/connecting components.
  • Nursing support: monitoring, medication administration per protocol, documentation, and post-procedure care.
  • Respiratory therapy (where applicable): ventilation coordination, oxygen delivery, and troubleshooting in ventilated patients.
  • Radiology support (where applicable): image guidance or post-procedure imaging workflows.

Many hospitals reinforce competence through simulation, supervised sign-offs, and periodic revalidation—particularly for low-frequency, high-risk procedures.

Environment and readiness requirements

A Thoracostomy kit is most effective when the environment supports controlled execution. Typical readiness elements include:

  • Adequate lighting and space for a sterile field
  • Continuous physiological monitoring per facility standards
  • Oxygen supply and airway management readiness (as required by protocol)
  • Reliable suction source (wall suction or portable suction) and regulators
  • Access to imaging and confirmation pathways as defined by local policy
  • Sharps disposal within immediate reach
  • A cleanable work surface and infection prevention supplies

In disaster or low-resource contexts, facilities may use modified workflows, but the minimum standard is still to protect sterility, staff safety, and reliable drainage system function.

Accessories and related hospital equipment

A Thoracostomy kit rarely stands alone. Depending on your facility pathway, you may need:

  • Chest drainage system (analog water-seal or digital system), often separate from the kit
  • Suction regulator (wall-mounted or portable) and connecting tubing
  • Sterile personal protective equipment (gown, gloves, eye/face protection as appropriate)
  • Skin preparation agents and sterile draping supplies (may be in the kit; may be separate)
  • Securement and dressing materials (may be included; often supplemented)
  • Local anesthesia and/or procedural medication supplies (typically separate and controlled)
  • Ultrasound and sterile probe cover (if used in your pathway)
  • Spare connectors/adapters approved by your facility to manage compatibility issues
  • Emergency backup supplies defined by protocol (for example, if a second drain is needed)

From a procurement standpoint, a common failure mode is purchasing an excellent kit but under-specifying the compatible drainage system and suction accessories—creating frontline workarounds.

Pre-use checks (practical and auditable)

Before opening a Thoracostomy kit, teams often perform quick, consistent checks that support safety, traceability, and compliance:

  • Confirm the correct kit type for the intended workflow (large-bore vs small-bore; adult vs pediatric; left/right not usually applicable but laterality matters clinically).
  • Verify packaging integrity: no tears, punctures, wet spots, broken seals, or crushed corners.
  • Check sterility indicators (type and location vary by manufacturer).
  • Check expiry date and any storage condition flags (temperature, humidity, light exposure—varies by manufacturer).
  • Confirm lot number and UDI (if available) for documentation and recall readiness.
  • Confirm component completeness to the extent possible without breaking sterility (some kits include a printed contents list).
  • Confirm compatibility with your chest drainage unit and connectors (barbed vs luer-style connectors, tubing diameter, approved adapters).
  • If using a drainage unit, confirm it is ready and functional (water seal fill level where applicable; intact chambers; no cracks; digital unit charged and initialized—varies by manufacturer).
  • Confirm suction availability and regulator function per biomed/engineering policy (wall suction performance checks are typically managed at the system level).

Documentation and governance essentials

Most facilities standardize documentation elements for invasive device placement. Common documentation fields include:

  • Indication and ordering pathway (as defined by facility policy)
  • Time-out completion and laterality confirmation
  • Device type, size, and manufacturer details (including lot/UDI where available)
  • Drainage unit type and settings (where relevant)
  • Immediate observations (patient tolerance, initial drainage characteristics)
  • Post-procedure plan (monitoring and escalation triggers)

For administrators, ensuring documentation templates exist in the electronic health record (EHR) reduces variability and supports quality audits.

How do I use it correctly (basic operation)?

A practical, high-level workflow (not a substitute for training)

The Thoracostomy kit supports a procedure that should be performed only by trained clinicians within an approved clinical governance framework. The steps below are intentionally high-level and operational, focusing on workflow reliability and device handling rather than technique instruction.

Always follow the manufacturer’s IFU and your facility’s protocol, including how your team performs site selection, analgesia/sedation, imaging, and confirmation.

Step-by-step workflow overview

  1. Confirm the clinical pathway – Verify that the Thoracostomy kit is the correct resource for the clinical plan (tube vs catheter approach; urgent vs planned). – Ensure appropriate staffing, monitoring, and escalation cover are in place.

  2. Select the correct kit configuration – Confirm intended tube/catheter type and size per protocol (sizing conventions such as French sizes are commonly used; selection criteria vary by facility and patient population). – Confirm whether the kit includes the tube/catheter or whether it is stocked separately.

  3. Prepare the environment and patient monitoring – Position the patient and equipment to maintain a stable sterile field and safe access. – Apply monitoring according to facility standards and ensure suction and oxygen are available. – Prepare sharps disposal and a clean work surface.

  4. Perform a formal time-out – Confirm patient identity, intended side, and planned equipment. – Confirm allergies and key risk flags as defined by your policy (for example, latex sensitivity where relevant). – Confirm that post-procedure imaging/confirmation workflow is available.

  5. Open the Thoracostomy kit and establish sterility – Open packaging using aseptic technique and verify sterility indicators as instructed. – Arrange components on the sterile field for efficient sequencing. – If additional sterile items are required, add them using sterile transfer technique.

  6. Prepare the drainage system (if used) – Set up the chest drainage unit according to its IFU (water seal, suction control, or digital initialization varies by manufacturer). – Confirm tubing connections are secure and appropriately routed to reduce trip hazards and accidental tension. – Confirm suction source and regulator function before connecting to the patient.

  7. Perform the procedure per clinical protocol – The kit may support blunt dissection placement, guidewire-based placement, or another approved approach depending on design. – Use only the components as intended; avoid improvised substitutions without prior risk assessment. – Maintain sterile technique throughout, including careful management of gloves, instruments, and tubing ends.

  8. Connect the tube/catheter to the drainage system – Make a secure connection using the intended connector type. – Route tubing to minimize dependent loops and kinks and to prevent pulling during patient movement. – If a one-way valve is used in your workflow, confirm orientation and function per IFU (varies by manufacturer and protocol).

  9. Secure the device and apply dressing – Securement method and dressing type vary by facility protocol and device design. – Aim for stable fixation, clear labeling, and protection against contamination and accidental dislodgement.

  10. Confirm function and initiate post-procedure monitoring – Observe the drainage unit for expected behavior (for example, presence of drainage, air leak indicators, or digital readings—depends on system). – Complete confirmation steps per protocol (often including imaging and clinical assessment). – Establish an observation plan and escalation triggers.

  11. Document the procedure and device details – Record device identifiers (lot/UDI), tube/catheter size, drainage unit type, and initial observations. – Document any deviations from standard workflow and the reason.

  12. Handover and ongoing care – Ensure the receiving team understands the drainage system type, suction settings (if used), and monitoring plan. – Ensure spare consumables (dressings, clamps if approved, securement supplies) are available in the care area.

“Typical settings” and what they generally mean (context: drainage systems)

The Thoracostomy kit itself usually has no adjustable “settings.” However, pleural drains are commonly attached to a drainage system that may be:

  • Water seal (gravity drainage without active suction): allows air/fluid to leave while reducing backflow; implementation varies by device design.
  • Suction-assisted drainage: negative pressure is applied via wall suction or a dedicated device to support drainage; target levels vary by protocol and device type.
  • Digital drainage systems: may display airflow, pressure trends, and/or leak status; configuration and calibration steps vary by manufacturer.

Commonly used suction levels are often described in clinical protocols using units such as cmH₂O, but the correct target is protocol-driven and patient-specific. For administrators and biomedical engineers, the key point is to ensure the suction regulator and drainage unit are compatible, functional, and supported by training, rather than focusing on a single “default” number.

Calibration and functional checks (what’s relevant)

  • Thoracostomy kit (disposable tray): typically no calibration. Primary checks are packaging integrity, sterility indicators, completeness, and expiry.
  • Drainage units (analog): functional checks include chamber integrity, proper setup, and absence of cracks or leaks.
  • Digital drainage units: may require initialization, zeroing, or self-tests. Procedures vary by manufacturer and should be included in staff training.
  • Suction regulators: may require periodic performance verification and preventive maintenance per biomedical engineering policy.

How do I keep the patient safe?

Safety starts before opening the kit

Patient safety in thoracostomy is a system property: training, environment, equipment, and team coordination. Practical pre-procedure safety practices commonly include:

  • Use a standardized checklist for invasive bedside procedures.
  • Confirm laterality and intended device type during time-out.
  • Ensure monitoring and escalation support are available (for example, airway support readiness per protocol).
  • Confirm all required equipment is present, including the drainage unit, suction source, and securement supplies.
  • Ensure infection prevention supplies are available and used correctly.

A key human factors insight: most failures occur at interfaces—between the Thoracostomy kit and the drainage unit, between tubing and suction, or between handoffs and documentation.

Sterile technique and contamination control

Because the device enters a sterile body space, sterility is a primary safety requirement:

  • Do not use if the sterile barrier is compromised.
  • Use aseptic opening and transfer techniques.
  • Avoid placing connectors or tubing ends on non-sterile surfaces.
  • Manage the sterile field to reduce clutter and instrument confusion.
  • Replace contaminated items rather than “wiping and continuing,” unless your policy and IFU explicitly permit a validated approach.

Monitoring and early recognition of complications (general)

Facilities typically define what post-procedure monitoring is required and how often it should occur. Monitoring commonly addresses:

  • Vital signs and oxygenation
  • Pain and patient comfort
  • Drainage system function (patency, air leak indicators, secure connections)
  • Insertion site condition and dressing integrity
  • Overall clinical trajectory and escalation triggers

Complications can include bleeding, infection, device malposition, subcutaneous emphysema, and equipment-related failures. The role of the Thoracostomy kit is not to eliminate these risks, but to support consistent, controllable execution and reliable documentation so abnormalities are noticed early.

Alarm handling and device-human interface considerations

Many drainage systems are passive and have no electronic alarms, but alarms and alerts can still arise from:

  • Digital drainage systems (device alerts, battery warnings, high/low pressure notifications)
  • Wall suction systems (facility-specific alarms or regulator issues)
  • Clinical monitors (oxygenation, respiratory rate, blood pressure alarms)

Practical strategies that reduce alarm-related confusion and delay include:

  • Train staff on the specific drainage system models used in your facility (do not assume cross-model equivalence).
  • Use consistent labeling of tubing and suction settings across units.
  • Minimize connector variety to reduce misconnections.
  • Standardize where the drainage unit is placed relative to the patient to reduce tipping and tension events.
  • Include alarm response steps in unit orientation and annual competency refreshers.

Policies that materially improve safety

From a hospital management perspective, high-impact policies typically include:

  • A single, standard Thoracostomy kit (or a controlled set of 2–3 kits) across the hospital, with documented exceptions.
  • Clear criteria for which departments stock which kit types and where they are stored.
  • A defined escalation pathway for complex placements (for example, interventional radiology or thoracic surgery).
  • Post-market surveillance habits: capture and review device complaints, near misses, and product defects by lot number.

How do I interpret the output?

What “output” means in thoracostomy workflows

A Thoracostomy kit is a procedural set and does not itself generate readings. “Output” is typically interpreted through:

  • Drainage output collected in a chest drainage system (volume and characteristics)
  • Air leak indicators (visual bubbling in analog water-seal systems or numeric/graphical data in digital systems)
  • Suction/pressure indicators (device-specific)
  • Patient response and confirmation workflows (clinical assessment and imaging per protocol)

For operational teams, it helps to define “output interpretation” as a competency not just for physicians, but also for nursing and ICU/ED staff who perform ongoing monitoring and documentation.

Common outputs and what teams generally look for

Depending on the drainage system type, teams commonly track:

  • Volume: measured in the collection chamber; trend over time is usually more meaningful than a single reading.
  • Appearance: color and consistency documentation can support clinical decision-making; interpretation depends on clinical context.
  • Air leak status:
  • Analog systems may show bubbling patterns in the water seal chamber.
  • Digital systems may display airflow values and trends (units and thresholds vary by manufacturer and protocol).
  • “Tidaling” or oscillation: some systems show fluid level movement that can suggest patency; interpretation is context-dependent.
  • Suction confirmation: analog systems may use a visual indicator; digital systems may display target and actual pressures.

Common pitfalls and limitations

Output interpretation is prone to errors that are operational rather than clinical:

  • False air leaks due to loose connections, cracked drainage units, or tubing defects.
  • Inaccurate volume readings if the drainage unit is tipped, not kept level, or if the unit’s scale is misread.
  • Documentation gaps when handovers occur without standardized recording of settings and outputs.
  • Cross-device confusion when multiple drainage unit models exist in the same facility, each with different visual cues.
  • Over-reliance on device data without correlating with the patient’s status and confirmation workflows.

Facilities reduce these pitfalls by standardizing drainage unit models where possible, implementing training specific to the models in use, and auditing documentation quality.

What if something goes wrong?

A practical troubleshooting checklist (device and workflow focused)

When issues occur, a structured approach helps distinguish patient deterioration from equipment malfunction. The checklist below is intentionally general; follow your clinical escalation policy.

If sterility is compromised before insertion

  • Stop and replace the Thoracostomy kit.
  • Document the issue and quarantine the compromised kit if required for investigation.

If there is an apparent air leak

  • Check all connections from patient to drainage unit and suction source.
  • Inspect tubing for cracks, loose fittings, or disconnections.
  • Confirm the drainage unit is set up correctly per its IFU (water seal level or digital initialization varies by manufacturer).

If there is little or no drainage when expected

  • Assess for tubing kinks, dependent loops, or clots/occlusion (management is protocol-driven).
  • Confirm the drainage unit is below the patient as required by the device IFU and facility policy.
  • Verify suction source function if suction is in use.

If suction is not achieved or unstable

  • Check wall suction availability and regulator settings.
  • Confirm that suction tubing is connected to the correct port and that there are no leaks.
  • For digital systems, verify battery/charging status and alarms.

If the tube/catheter becomes dislodged or the system disconnects

  • Treat as an urgent safety event per facility protocol.
  • Stabilize the patient and escalate immediately.
  • Preserve device components if required for incident review.

If equipment appears defective

  • Stop using the defective component where safe to do so and switch to a backup per policy.
  • Record lot/UDI and details of the failure mode.
  • Notify biomedical engineering for associated equipment (suction regulators, digital drains) and report to the manufacturer through your procurement/quality channels.

When to stop use (general)

Stop and reassess/escalate when:

  • Packaging sterility is compromised before use.
  • A component breaks, leaks, or behaves inconsistently with the IFU.
  • The drainage system cannot maintain a seal or function despite basic checks.
  • Patient status worsens or unexpected findings occur (clinical escalation is required).

When to escalate to biomedical engineering or the manufacturer

Escalate to biomedical engineering when the issue involves reusable medical equipment or hospital infrastructure, such as:

  • Wall suction performance, regulators, gauges, or connectors
  • Digital drainage unit alarms, charging failures, sensor errors, or software issues
  • Recurrent failures suggesting a system-level problem (training, compatibility, or maintenance)

Escalate to the manufacturer (through your procurement/quality pathway) when:

  • There are suspected defects in sterile disposable components
  • Multiple complaints cluster around a lot number or time period
  • IFU clarity is inadequate and contributes to misuse risk
  • You need formal compatibility statements or change notifications

Good practice for hospitals: capture complaints with photos (where policy permits), retain packaging, record lot/UDI, and file an internal incident report so trends can be analyzed.

Infection control and cleaning of Thoracostomy kit

Core principles: sterile, single-use, and traceable

In many hospitals, a Thoracostomy kit is designed as single-use sterile medical equipment. If labeled single-use, it should not be reprocessed. Reuse can create risks including:

  • Loss of sterility assurance
  • Material degradation (especially plastics and coatings)
  • Performance changes not detectable by visual inspection
  • Regulatory non-compliance

However, practices vary globally. Some facilities may use reusable instruments alongside disposable components. In those cases, infection control must be based on validated reprocessing instructions (IFU), local regulations, and an auditable sterile services process.

Cleaning vs disinfection vs sterilization (general definitions)

  • Cleaning: physical removal of soil and organic material; a prerequisite for effective disinfection or sterilization.
  • Disinfection: reduction of microorganisms to a level considered safe for specific contexts; does not reliably destroy all spores.
  • Sterilization: validated process intended to eliminate all forms of microbial life; required for items that enter sterile body sites (“critical” items).

Most components in a Thoracostomy kit that contact sterile tissue are treated as critical items and are provided sterile and intended for one procedure.

High-touch points and contamination pathways

Even when the kit is disposable, infection control risks occur around it. High-touch points commonly include:

  • Outer packaging surfaces handled during transport and storage
  • Procedure tray edges and any non-sterile surfaces near the sterile field
  • Connector ends of tubing (high risk if they touch non-sterile surfaces)
  • Suction regulators and wall suction knobs (frequently touched, often overlooked)
  • The exterior of the drainage unit (handled during positioning and measurement)
  • Ultrasound machine surfaces and probes (if used), including keyboards and gel bottles
  • Bed rails, monitor controls, and workstations used during the procedure

Operational best practice is to assign responsibility for wiping specific surfaces (for example, one person handles non-sterile equipment while the operator maintains sterility).

Example cleaning and infection-control workflow (non-brand-specific)

Before the procedure

  • Perform hand hygiene and don appropriate PPE.
  • Clean and disinfect the work area and any reusable equipment that will be in the immediate field (per hospital policy).
  • Confirm sterile supplies are stored appropriately and packaging is intact.

During setup

  • Open the Thoracostomy kit using aseptic technique.
  • Keep non-sterile items (phones, pens, non-sterile ultrasound controls) away from the sterile field.
  • Use sterile covers for equipment that must enter the sterile area (for example, ultrasound probes), per protocol.

After the procedure

  • Dispose of sharps immediately into approved containers.
  • Dispose of single-use components as clinical waste per policy (including blood/fluid-contaminated items).
  • Clean and disinfect reusable medical equipment surfaces (drainage unit exterior if reused is uncommon; suction regulators and wall suction surfaces are routinely cleaned).
  • Perform terminal cleaning of the procedural area per local standards, including high-touch surfaces.
  • Document device identifiers and any contamination events, and report breaches via your infection prevention process.

Storage and transport considerations (often overlooked)

Infection prevention is also supply-chain dependent:

  • Store Thoracostomy kit boxes off the floor, protected from moisture and crushing.
  • Rotate stock using FIFO/FEFO practices (first-expired, first-out).
  • Avoid storing sterile kits in areas with uncontrolled temperature/humidity if the manufacturer specifies limits (varies by manufacturer).
  • Use sealed transport bins for moving kits to ED/ICU/OR to reduce packaging damage and contamination.

These steps reduce both infection risk and waste from damaged sterile barriers.

Medical Device Companies & OEMs

Manufacturer vs. OEM (Original Equipment Manufacturer): why it matters

In medical device procurement, the “manufacturer” is the legal entity responsible for the device under applicable regulations. An OEM may design and/or produce a product that is later branded and sold by another company (often called private labeling). OEM relationships are common across disposable procedure kits, tubing sets, connectors, and accessories.

For a Thoracostomy kit, OEM dynamics can affect:

  • Quality management (for example, who controls change management and process validation)
  • Supply continuity (single-source components can create vulnerability)
  • Complaint handling and post-market surveillance (who investigates failures and issues field safety notices)
  • IFU quality and training materials (who authors and updates them)
  • Service and support (less relevant for disposable kits, but relevant for associated equipment)

How OEM relationships impact quality, support, and service

From a hospital perspective, the key is not whether an OEM is involved, but whether responsibilities are clear and auditable. Practical implications include:

  • A branded supplier may provide frontline support, but root-cause investigations may occur at the OEM.
  • Product changes may occur due to OEM component substitutions; strong change-notification processes reduce surprises.
  • Documentation may differ across regions even for similar products (labeling language, regulatory marks, UDI availability).

When evaluating a Thoracostomy kit supplier, procurement teams often request clarity on who manufactures critical components (tube/catheter, guidewire, connectors) and who holds regulatory responsibility in the purchasing country.

Top 5 World Best Medical Device Companies / Manufacturers

The companies below are example industry leaders based on broad global visibility across medical devices. Portfolios and availability vary by country, and not every company listed necessarily markets a Thoracostomy kit in every region.

  1. Becton, Dickinson and Company (BD) – BD is widely recognized for large-scale manufacturing and global distribution of medical consumables and clinical devices. – Its portfolio commonly spans vascular access, medication delivery, syringes, needles, and infection prevention-related products. – Many hospitals value BD for consistency of supply and standardized consumable categories, though specific thoracostomy-related offerings vary by market.

  2. Teleflex – Teleflex is known internationally for critical care and surgical access product categories, with a footprint in hospitals and emergency care environments. – Across regions, Teleflex-branded lines often focus on catheters, airway and respiratory care, and procedure-enabling disposables. – Where available, Teleflex products may be considered in pleural access and drainage workflows; exact configurations and kit contents vary by manufacturer and country.

  3. B. Braun – B. Braun has a broad global reputation in hospital equipment and medical consumables, including infusion therapy, regional anesthesia, and surgical products. – The company operates in many countries with localized support models and established hospital relationships. – Depending on the market, B. Braun may supply components relevant to thoracic procedures (for example, sterile disposables and drainage-related items), but availability is country-dependent.

  4. Getinge – Getinge is internationally visible in critical care, surgical, and sterile processing ecosystems, with products used in operating rooms and intensive care settings. – The company is often associated with hospital infrastructure and advanced therapy support categories, alongside selected consumables. – In pleural drainage workflows, Getinge’s relevance may be through associated systems used in cardiothoracic care; specific Thoracostomy kit offerings vary by region and portfolio.

  5. ICU Medical (including legacy portfolios acquired over time) – ICU Medical is known for infusion-related medical equipment and consumables and has expanded its footprint through acquisitions in certain device categories. – Many hospitals encounter ICU Medical primarily through infusion systems and disposable sets, with global reach that varies by segment. – Depending on regional product availability, ICU Medical or legacy lines may be present in critical care consumables adjacent to pleural procedures; confirm local portfolio and regulatory listings.

Vendors, Suppliers, and Distributors

Vendor vs supplier vs distributor: practical differences

In day-to-day hospital purchasing, these terms are sometimes used interchangeably, but they can imply different roles:

  • Vendor: the entity you contract with to purchase goods/services. A vendor might be a manufacturer, distributor, or reseller.
  • Supplier: a broad term for any party providing products (and sometimes services). A supplier might include OEMs, private-label brands, or regional wholesalers.
  • Distributor: a logistics and commercial intermediary that stocks products, manages warehousing and delivery, and may provide value-added services such as kitting, demand forecasting, and returns processing.

For a Thoracostomy kit, distributors can be especially important because kits are consumable and time-sensitive: stockouts directly impact emergency readiness.

What distributors typically add (beyond delivery)

Depending on the market and contract type, distributors may provide:

  • Inventory management programs (par level management, automated replenishment)
  • Procedure kitting and custom packs (sometimes assembling hospital-specific trays)
  • Cold chain and controlled storage (less relevant for most Thoracostomy kit products, but relevant for adjacent medications)
  • Regulatory and import documentation support
  • Training logistics coordination with manufacturers
  • Returns handling, recall execution support, and complaint intake

For procurement leaders, a key question is whether the distributor can support 24/7 delivery to ED/ICU/OR environments and whether they can provide lot/UDI traceability at the unit level.

Top 5 World Best Vendors / Suppliers / Distributors

The organizations below are example global distributors with broad healthcare supply roles. Regional presence, product categories, and the ability to supply a Thoracostomy kit vary by country and contract structure.

  1. McKesson – McKesson is widely known as a large healthcare distribution organization with deep logistics capabilities in certain markets. – Typical strengths include high-volume distribution, inventory programs, and support for standardized hospital consumables. – Buyer profiles commonly include hospitals and integrated delivery networks, though specific product availability depends on country and contracting.

  2. Cardinal Health – Cardinal Health is recognized for healthcare distribution and supply chain services, with a presence in hospital consumables and logistics-oriented offerings. – Many health systems engage Cardinal Health for supply standardization initiatives and distribution scale. – Depending on region, offerings may include procedure kits and private-label consumables; portfolio varies by country.

  3. Owens & Minor – Owens & Minor is known for medical and surgical supply distribution and supply chain services in select markets. – The organization often supports hospitals with logistics, warehousing, and product availability programs, especially for high-turnover consumables. – For procedure kits, value often comes from consistent fulfillment and contract management rather than direct manufacturing.

  4. Medline Industries – Medline operates as both a manufacturer and distributor in many regions, with a large footprint in medical-surgical consumables. – Hospitals often work with Medline for standardized packs, private-label products, and broad-category supply coverage. – For a Thoracostomy kit, the relevant offering may be a branded kit, a custom tray program, or distribution of third-party brands—this varies by market.

  5. Zuellig Pharma – Zuellig Pharma is widely recognized in parts of Asia for healthcare distribution and logistics services. – Capabilities often include warehousing, regulatory support, and last-mile delivery in complex geographies. – Typical buyer profiles include hospitals and health systems requiring dependable supply of essential medical equipment and consumables; country coverage varies.

Global Market Snapshot by Country

India

Demand for Thoracostomy kit products is driven by trauma care needs, rising ICU capacity, expanding emergency medicine services, and increasing surgical volumes in both public and private sectors. Procurement often combines domestic manufacturing for basic consumables with imports for specific branded clinical device configurations, with significant price sensitivity in many tenders. Urban tertiary centers typically have better access to standardized kits, drainage units, and trained teams, while rural facilities may rely on limited inventories and referral pathways.

China

China’s market is shaped by large hospital networks, ongoing investment in emergency and critical care capacity, and strong domestic medical device manufacturing. Centralized procurement and volume-based purchasing approaches can influence brand availability and pricing, with hospitals balancing standardization and cost containment. Urban hospitals generally have broader access to modern drainage systems and training, while smaller or rural facilities may have fewer device options and slower replacement cycles.

United States

In the United States, Thoracostomy kit utilization is closely tied to trauma systems, emergency departments, ICUs, and perioperative services, with strong emphasis on standardization, documentation, and traceability. Group purchasing organizations and integrated delivery networks heavily shape procurement, and many facilities prefer procedure trays that reduce variability and support compliance. The service ecosystem includes robust clinical education and biomedical support, though product consolidation and supply disruptions can still affect readiness.

Indonesia

Indonesia’s demand is influenced by trauma burden, respiratory disease management needs, and gradual expansion of critical care services across an archipelago geography. Import dependence can be significant for branded kits and certain drainage systems, with distribution complexity affecting consistency outside major urban centers. Large hospitals in key cities are more likely to standardize Thoracostomy kit configurations, while remote areas may face access constraints and rely on referral systems.

Pakistan

Pakistan’s market reflects the needs of busy emergency departments, trauma care, and respiratory disease pathways, with procurement split between public tenders and private hospital purchasing. Many facilities depend on imported devices for specific configurations, while local supply may cover some consumables and basic components. Urban centers typically have better coverage for standardized kits and trained personnel, while rural access and consistent stocking can be challenging.

Nigeria

In Nigeria, demand is driven by emergency care needs, trauma, and the gradual expansion of surgical and ICU services, particularly in major cities. Import dependence is common for many regulated medical devices and procedure kits, and distribution reliability can vary by region. Urban tertiary facilities may have stronger supplier relationships and more consistent inventories, while rural settings can face gaps in availability, training, and supporting equipment such as drainage units and suction regulators.

Brazil

Brazil’s market combines a large public health system with a substantial private sector, both of which drive demand for pleural drainage readiness in emergency and surgical care. Local manufacturing exists for various medical consumables, while certain specialized kits and associated systems may still be imported depending on hospital preference and regulatory pathways. Access is generally stronger in urban and coastal regions, with variability in procurement cycles and service support across states.

Bangladesh

Bangladesh’s growing hospital sector and high patient volumes support steady demand for Thoracostomy kit products, particularly in tertiary urban centers. Import dependence is common for branded kits and some drainage systems, while cost containment remains a central procurement factor. Rural facilities may have limited access to standardized kits and supporting infrastructure, making supply planning and referral coordination important for patient pathways.

Russia

Russia’s market includes a mix of domestic production and imports for medical equipment, with availability influenced by regulatory requirements and broader supply-chain constraints. Hospitals often prioritize essential procedure capability, but brand selection and spare-part availability for associated equipment can vary. Urban centers typically have better access to standardized consumables and specialist services than remote regions.

Mexico

Mexico’s demand is supported by trauma care, emergency services, and surgical volume across public and private providers. Many hospitals rely on imported kits or components, while local distribution networks play a large role in ensuring consistent availability across states. Urban private hospitals may adopt more standardized procedure trays and modern drainage systems, while rural access and training capacity can be uneven.

Ethiopia

In Ethiopia, demand is linked to expanding hospital capacity, emergency care development, and critical care investment in major cities. Import dependence is high for many regulated medical devices, and procurement may be shaped by public purchasing systems, donor-supported programs, or centralized supply models. Urban tertiary centers typically have better access to Thoracostomy kit supplies and trained staff, while rural facilities may face limited availability and supporting infrastructure challenges.

Japan

Japan’s market is characterized by high standards for device quality, established clinical protocols, and strong hospital infrastructure, supporting consistent use of standardized procedure equipment. Domestic manufacturers and well-regulated import channels provide a stable supply ecosystem, with emphasis on documentation and reliability. Advanced centers may adopt digital drainage technologies and structured training, while smaller facilities still maintain core pleural drainage capability through standardized stocking.

Philippines

In the Philippines, demand is driven by growth in private hospitals, ongoing public sector upgrades, and emergency/critical care needs. Import dependence is significant for many branded medical devices, and distribution across islands can complicate consistent stocking and rapid replenishment. Metro-based tertiary centers generally have better access to standardized Thoracostomy kit configurations and supporting drainage systems than smaller provincial hospitals.

Egypt

Egypt’s market reflects strong demand in busy public hospitals and an expanding private sector, with trauma and surgical care supporting ongoing use of pleural drainage procedures. Procurement may include both local manufacturing for selected consumables and imports for specific kit designs and associated devices. Urban centers tend to have better supplier coverage and training access than rural areas, where stocking consistency and equipment maintenance can be limiting factors.

Democratic Republic of the Congo

In the Democratic Republic of the Congo, access to Thoracostomy kit supplies is often constrained by limited infrastructure, variable procurement capacity, and reliance on imports or humanitarian supply chains. Urban referral hospitals may maintain basic pleural drainage capability, but consistent availability of standardized kits and compatible drainage systems can be challenging. Rural access is frequently limited, making logistics, training, and safe reuse avoidance particularly important operational considerations.

Vietnam

Vietnam’s demand is supported by rapid healthcare investment, hospital modernization, and increased surgical and critical care capacity, especially in major cities. Import dependence remains important for many branded devices, while domestic manufacturing is growing in selected medical consumable categories. Urban tertiary centers are more likely to standardize kits and adopt newer drainage equipment, while provincial facilities may face variability in device options and training resources.

Iran

Iran’s medical device landscape includes meaningful domestic manufacturing capacity, partly shaped by import constraints and a focus on local supply continuity. Hospitals may use a mix of domestically produced consumables and imported components where available, with procurement pathways influenced by regulation and availability. Urban centers generally have stronger access to standardized kits and service support than remote regions, where supply continuity can be more difficult.

Turkey

Turkey has a well-developed healthcare system with strong hospital capacity in major cities and a growing medical device and distribution ecosystem. Public tenders and private hospital procurement both influence brand availability, and the country often serves as a regional hub for distribution and manufacturing partnerships. Urban access to standardized Thoracostomy kit products and supporting drainage systems is typically strong, with more variability in smaller or remote facilities.

Germany

Germany’s market emphasizes regulatory compliance, product quality, and standardized clinical workflows, supporting consistent demand for procedure kits and compatible drainage systems. A mature supplier ecosystem and strong logistics infrastructure generally support reliable procurement and replenishment for hospitals. Advanced centers often integrate device standardization with robust training and documentation, while smaller facilities still maintain readiness through established supply chains and protocols.

Thailand

Thailand’s demand is supported by public health investment, expanding ICU and surgical services, and a significant private sector that includes medical tourism in major cities. Imports play an important role for many branded medical devices, while local distribution networks determine availability and after-sales support. Urban hospitals are more likely to standardize Thoracostomy kit configurations and adopt modern drainage systems, while rural facilities may face constraints in inventory depth and specialized training access.

Key Takeaways and Practical Checklist for Thoracostomy kit

  • Standardize Thoracostomy kit types across the hospital to reduce variability and training burden.
  • Confirm whether your Thoracostomy kit includes the tube/catheter or if it is a separate SKU.
  • Align kit selection with your clinical pathways (large-bore vs small-bore) before contracting.
  • Require an itemized contents list from suppliers to prevent hidden component gaps.
  • Verify connector and tubing compatibility with your existing chest drainage units.
  • Treat the drainage unit and suction regulator as part of the same safety system as the Thoracostomy kit.
  • Build a minimum equipment checklist that includes suction, drainage unit, dressings, and securement supplies.
  • Use a formal time-out process that includes laterality and device configuration confirmation.
  • Do not use a Thoracostomy kit if the sterile barrier is damaged, wet, torn, or unsealed.
  • Enforce expiry-date checks at both storage and point-of-use to prevent last-minute waste.
  • Implement FEFO inventory rotation for sterile procedure kits to reduce expiries.
  • Capture lot numbers and UDI (if available) in documentation for recall readiness.
  • Define who documents device identifiers in the EHR to avoid missing traceability fields.
  • Stock Thoracostomy kit products in clearly labeled, standardized locations in ED, ICU, and OR.
  • Ensure 24/7 access to kits in areas where emergency procedures may occur.
  • Use simulation-based training to maintain competency for low-frequency, high-risk procedures.
  • Train staff on the specific drainage unit models used in your facility to reduce interpretation errors.
  • Minimize the number of drainage system models to reduce human factors risk and supply complexity.
  • Include suction regulator performance checks in biomedical preventive maintenance schedules.
  • Require manufacturers to provide IFUs in local language(s) as required by regulation.
  • Confirm single-use labeling and prohibit unauthorized reprocessing of disposable kit components.
  • Define cleaning responsibility for wall suction knobs, monitor controls, and other high-touch surfaces.
  • Keep connector ends off non-sterile surfaces to reduce contamination risk.
  • Use a structured troubleshooting checklist for leaks, occlusions, and suction instability.
  • Escalate suspected equipment failures to biomedical engineering when infrastructure is involved.
  • Report disposable component defects to the vendor with photos, lot number, and failure description.
  • Quarantine suspect lots when multiple failures cluster to support investigation.
  • Specify packaging durability requirements if kits are transported frequently within the hospital.
  • Evaluate suppliers on supply continuity and backorder performance, not price alone.
  • Ask suppliers about change-notification practices for component substitutions and packaging updates.
  • Consider custom kitting only if you can maintain strict version control and staff retraining processes.
  • Ensure sharps disposal is within reach before the kit is opened to reduce needlestick risk.
  • Document drainage system type and configuration so downstream teams can interpret output consistently.
  • Audit documentation quality periodically to identify unit-to-unit variability and training needs.
  • Establish escalation pathways for complex cases so staff do not rely on kit availability as a substitute for expertise.
  • Plan for rural or satellite facilities with simplified, robust kit configurations and clear referral pathways.
  • Consider sustainability impacts (waste volume, packaging) alongside safety and readiness requirements.
  • Use vendor scorecards that include training support, complaint handling speed, and traceability performance.
  • Keep a contingency stock level for mass-casualty readiness where relevant to your risk profile.
  • Validate that procurement contracts cover both consumable kits and any associated reusable equipment support.
  • Ensure infection prevention teams review kit setup workflows to address high-touch contamination points.
  • Review incident reports for tubing misconnections and leaks to guide connector standardization.
  • Maintain a clear separation between sterile kit components and non-sterile accessories during setup.
  • Include Thoracostomy kit governance in bedside procedure policy updates and annual safety reviews.

If you are looking for contributions and suggestion for this content please drop an email to info@mymedicplus.com